Search results for "Extravascular Lung Water"

showing 2 items of 2 documents

B-Lines for the assessment of extravascular lung water: Just focused or semi-quantitative?

2020

BACKGROUND B-lines as typical artefacts of lung ultrasound are considered as surrogate measurement for extravascular lung water. However, B-lines develop in the sub-pleural space and do not allow assessment of the whole lung. Here, we present data from the first observational multi-centre study focusing on the correlation between a B-lines score and extravascular lung water in critically ill patients suffering from a variety of diseases. PATIENTS AND METHODS In 184 adult patients, 443 measurements were obtained. B-lines were counted and expressed in a score which was compared to extravascular lung water, measured by single-indicator transpulmonary thermodilution. Appropriate correlation coe…

AdultLung DiseasesMalemedicine.medical_specialtyOxygenation indexCritical IllnessThermodilutionSensitivity and Specificity03 medical and health sciencesYoung Adult0302 clinical medicineInternal medicinemedicineHumans030212 general & internal medicineProspective StudiesLungAgedUltrasonographyAged 80 and overLungReceiver operating characteristicCritically illbusiness.industry030208 emergency & critical care medicineGeneral MedicineOxygenationMiddle Agedrespiratory tract diseasesLung ultrasoundAnesthesiology and Pain MedicineLung watermedicine.anatomical_structureExtravascular Lung WaterCardiologyFemalebusinessSemi quantitativeActa anaesthesiologica ScandinavicaREFERENCES
researchProduct

Echocardiographic and lung ultrasound characteristics in ambulatory patients with dyspnea or prior heart failure.

2013

Purpose Lung ultrasound (LUS) represents a novel, noninvasive method in the assessment of extravascular lung water. We investigated the utility of LUS in ambulatory subjects with dyspnea or prior heart failure (HF). Methods We studied 81 ambulatory subjects with HF history or dyspnea who underwent transthoracic echocardiography (TTE) with LUS of 8 zones. Subjects with heart transplantation or pulmonary conditions known to interfere with LUS were excluded. A reviewer blinded to the clinical data performed echocardiographic measurements and quantified B-lines (reverberation artifacts arising from the pleural line). Results Of 81 subjects, 74 (91%) (median age 66 years, 39% men, median left ve…

Malemedicine.medical_specialtymedicine.medical_treatmentBlood PressureRisk AssessmentSensitivity and SpecificityNuclear Medicine and ImagingInternal medicinemedicine.arterymedicineAmbulatory CareHumansRadiology Nuclear Medicine and imagingSingle-Blind MethodLungDyspnea; Echocardiography; Heart failure; Lung ultrasound; Aged; Ambulatory Care; Blood Pressure; Dyspnea; Echocardiography; Extravascular Lung Water; Female; Heart Failure; Humans; Lung; Male; Middle Aged; Prognosis; Reproducibility of Results; Risk Assessment; Sensitivity and Specificity; Single-Blind Method; Stroke Volume; Cardiology and Cardiovascular Medicine; Radiology Nuclear Medicine and ImagingAgedHeart transplantationHeart FailureLung ultrasoundEjection fractionbusiness.industryReproducibility of ResultsStroke VolumeStroke volumeMiddle Agedmedicine.diseasePrognosisBlood pressureDyspneaEchocardiographyHeart failureAmbulatoryPulmonary arteryExtravascular Lung WaterCardiologyVentricular pressureFemaleRadiologyCardiology and Cardiovascular MedicinebusinessEchocardiography (Mount Kisco, N.Y.)
researchProduct